FL 200 Oil in Water Analyser
General
| Type
|
UV Fluorescence |
| Range:
|
0 - 10 PPM Aromatics Hydrocarbons
|
| Accuracy:
|
+/- 3 PPB |
| Repeatability:
|
|
Mechanical
|
Flow Rate: |
0 - 5 L/Min, Typically 0.5 L/Min |
|
Sample Temperature: |
0 to 60oC |
|
Electrical Operating Temperature: |
0 to 60oC |
|
Storage Temperature: |
-40 to 85oC |
Electrical
|
Power |
110 - 120 VAC, 50/60 Hz
220 - 240 VAC, 50/60 Hz
+ Integral 12 VDC battery |
Communications
|
Analogue |
4 - 20 mA |
|
Digital |
Port 1: RS232 for PC, Modem, or Modbus Port 2: RS232 for on-line
printer |
|
Alarms |
2 Relays |
Certification
|
European |
CE Marked |
|
CENELEC |
EExd IIB T4 |
|