Trace hydrogen sulphide measurement, ATEX certified
SS2100 H2S
low level H2S measurement
rapid speed of response
high accuracy
low cost of ownership
Using a laser to monitor low levels of hydrogen sulphide offers a number of key benefits.
This robust, non-contact analyser is highly accurate with an extremely rapid speed of response, and has led the industry to a new era. The ability to monitor water vapour in near real time has led to signifcantly improved confidence in the measurement, and improved process efficiencies.
The speed of response of the analyser enables rapid detection of, and recovery from, process upsets, allowing easier diagnosis of plant problems, and rapid return to normal process level. This allows quick return to shipping product.
- Non contact with the process gas - the active measurement system is mounted behind a window, making this technique a robust measurement system with corossive and contaminated gas streams.
- High accuracy - the initial accuracy is maintained as there are no components in the measurement system that will cause progressive drift.
- Rapid response - near real time process control can be achieved, improving process efficiency and, in some cases, allowing the cost of process plant to be reduced.
- Low maintenance - with no consumables or moving parts, this analyser has very low operational costs and can provide a short return on investment.
GENERAL |
||||
|
Measurement |
Hydrogen sulphide |
|||
|
Measurement principle |
Absorption spectroscopy using a tunable diode laser |
|||
|
Range |
0 to 10 /20 /50 /100 /500 /1000 /2500 or 5000 ppmv |
|||
|
Other ranges available on request |
||||
|
Analogue output |
4 to 20 mA configurable |
|||
|
Repeatability |
Range dependent * |
|||
|
Response time |
Typically less than 20 seconds* |
|||
|
Operational temp. range |
-20 to 50 °C |
|||
|
LCD display |
Concentration, cell pressure & temp. & diagnostics |
|||
Certification |
||||
|
European |
CE marked |
|||
|
ATEX/IECEx |
Ex II 2G, Ex d IIB+H2 T4, II2D ExtD A21 IP66 T135°C |
|||
Shipping |
||||
|
Shipping weight |
Approx 86 Kg |
|||
MECHANICAL |
||||
|
Dimension |
670 H x 470 W x 377 D mm |
|||
|
Material (wetted parts) |
316 stainless steel standard * |
|||
|
ATEX Box |
Aluminium epoxy coated |
|||
|
Pressure to cell |
70 kPaG (10 PSIG) |
|||
|
Pressure to sample cabinet |
Between 140 to 350 kPaG 920 to 50 PSIG) |
|||
|
Sample flow rate |
0.1 to 4 S l/min.* |
|||
|
Ingress protection |
IP66 |
|||
ELECTRICAL |
||||
|
Power |
100 to 240 VAC, 50 to 60 Hz, 300 W |
|||
Outputs |
||||
|
Current |
Qty 2, isolated 4 to 20 mA, 1200 Ω at 24VDC |
|||
|
Relay contacts |
Qty 1 general fault, Qty 1 Hi/Lo alarm |
|||
|
Digital 1 |
RS-485 half duplex & 10/100 ethernet (standard) |
|||
|
Digital 2 |
RS-232 (optional) |
|||
|
Protocols |
Modbus Gould RTU or Danial RTU or ASCII |
|||
|
* Application dependent |
||||
|
All specifications subject to change |
||||

IMA builds bespoke integrated sample systems to provide full measurement systems.
Contact us to discuss your requirements for:
- sample probes
- fast loops
- heated tube bundles
- pressure reduction & pressure relief
- filtration
DATASHEET:
Hydrogen Sulphide Gas analyser SS2100i-1 Single ATEX enclosure
VIDEO:
SpectraSensors overview of technology
APPLICATION NOTES:
Coming soon: please visit again.
TECHNICAL BULLETINS:
Coming soon: please visit again.
DRAWINGS: