Water in oil monitor, by-pass system
DC-1510
0% to 50%
ATEX Zone 1
rapid response
A water in oil transmitter designed for on-line monitoring of oil and other non-conductive liquids.
This device provides on-line monitoring of crude, fuel, hydraulic and lubricating oils for traces of water with equal accuracy, for alerting operators to the danger of water breakthrough, or as a quality control check on custody transfer applications.
The DC-1510 monitor operates on the capacitance principle: the higher the water cut the greater the capacitance. The microprocessor-based electronics incorporate sophisticated algorithms to compensate for temperature and dielectric variations, which facilitates high resolution and stable results.
Robust engineering, combined with a 4 to 20 mA output, makes this a reliable and easy to use instrument for water or base sediment and water (BS&W) for precise measurement of water volume between 0 % and 80 %.
The DC-1510 is suitable for by-pass or slip-stream type installations. This method can be installed on systems with small pipe diameters, offering ease of calibration and sampling. (See DC-3510 for direct insertion option.)
Installation of the DC-1510 is simple. Adequate flow is required to ensure that 'free' water does not drop out within the monitor or sample system, and that the take off point provides a representative sample.
|
![]() |
DC-1510-NPT Port connections: 1" NPT Max. working pressure: 150 Bar (2160 PSI) |
|
![]() |
Also available with 3/4" NPT ports |
|
|
DC-1510F-H Port connections: 1" RF Flanged both sides 150, 300, 600, 900 or 1500#ANSI |
|
|
|
Also available with 2" RF ports |
|
|
|
|
|
|
|
|
DC-1510F-U |
|
|
|
Also available with 2" RF ports |
|
|
|
|
|
|
DC-1510F-Z |
|
|
|
Also available with 2" RF ports |
![]() |
|
GENERAL |
||||
|
Measurement |
Water-in-oil, BS&W, Water cut |
|||
|
Measurement principle |
Advanced digital capacitance |
|||
|
Water in oil range |
0 to 50 % standard |
|||
|
(50 to 80 % optional) |
||||
|
Analogue output |
0 to 50 % (0 to 500,000 ppm) configurable |
|||
|
Resolution |
0.001 % (10 ppm) |
|||
|
Accuracy |
0.01 % (100 ppm) |
|||
|
Repeatability |
Up to 0.01 % (100 ppm) |
|||
|
Temp. compensation |
0 to 260 °C |
|||
|
Temp. stability |
0.0015 % (15 ppm) water/°C |
|||
Certification |
||||
|
European |
CE marked |
|||
|
ATEX |
Ex II 2G, Ex d IIB T4, Zone 1 |
|||
|
CSA |
Class 1, Div. 1, Gr. C&D |
|||
|
Corrosion Protection |
NACE MR-0175/ISO 15156 2009 sour service compliant |
|||
Shipping |
||||
|
DC-1510-NPT |
19.5 Kg |
|||
|
DC-1510-F-H |
29 to 68 Kg |
|||
|
DC-1510F-U |
24 to 44 Kg |
|||
|
DC-1510F-Z |
24 to 44 Kg |
|||
|
DC-1510 - all versions |
26 cm x 28 cm x 86 cm |
|||
MECHANICAL |
||||
|
Material (wetted parts) |
316 Stainless standard (Monel 400, Inconel 625 & Duplex 2205 optional) |
|||
|
O-ring material |
Viton A standard (Nitrile & PTFE optional) |
|||
|
Ingress protection |
IP66 compliant |
|||
Maximum Operating Pressures |
||||
|
Temperature |
-6 to 38 °C |
65 °C |
93 °C |
121 °C |
|
Class 150 |
18.5 Bar |
17 Bar |
16 Bar |
15 Bar |
|
Class 300 |
49 Bar |
48 Bar |
47.5 Bar |
47 Bar |
|
Class 600 |
98 Bar |
96.5 Bar |
95 Bar |
94 Bar |
|
Class 900 |
147 Bar |
145 Bar |
143 Bar |
140.5 Bar |
|
Max. fluid temperature |
135 °C (260 °C optional) |
|||
|
Max. ambient temperature |
+85 °C |
|||
|
Electrical operating temp. |
-40 °C to +85 °C |
|||
|
Storage temperature |
-40 °C to +85 °C |
|||
ELECTRICAL |
||||
|
Power |
24 V DC@ 150 mA floating |
|||
|
Conduit size |
3/4" NPT, 1" NPT & M20 |
|||
Analogue output |
||||
|
Current |
4 to 20 mA isolated, self-powered |
|||
|
Maximum load |
600 Ω |
|||
|
Isolating volts |
500 V peak |
|||
Alarm Relay Setpoint |
||||
|
Relay contacts |
SPST 2 amp@ 24 V non-inductive |
|||
|
Delay adjustable |
0 to 43 million seconds |
|||
|
Hysteresis adjustable |
0 to 49.9 % |
|||
Digital Interface |
||||
|
Output 1 |
RS-232 full duplex (max. 100 m) |
|||
|
Output 2 |
RS-485 (max. 1500 m) |
|||
|
Speed |
9600 Baud |
|||