Water in oil monitor, by-pass system

DC-1510

0% to 50%
ATEX Zone 1
rapid response

 A water in oil transmitter designed for on-line monitoring of oil and other non-conductive liquids.

This device provides on-line monitoring of crude, fuel, hydraulic and lubricating oils for traces of water with equal accuracy, for alerting operators to the danger of water breakthrough, or as a quality control check on custody transfer applications.

The DC-1510 monitor operates on the capacitance principle: the higher the water cut the greater the capacitance. The microprocessor-based electronics incorporate sophisticated algorithms to compensate for temperature and dielectric variations, which facilitates high resolution and stable results.

Robust engineering, combined with a 4 to 20 mA output, makes this a reliable and easy to use instrument for water or base sediment and water (BS&W) for precise measurement of water volume between 0 % and 80 %.

The DC-1510 is suitable for by-pass or slip-stream type installations. This method can be installed on systems with small pipe diameters, offering ease of calibration and sampling. (See DC-3510 for direct insertion option.)

Installation of the DC-1510 is simple.  Adequate flow is required to ensure that 'free' water does not drop out within the monitor or sample system, and that the take off point provides a representative sample.

 

 

DC-1510-1-NPT

DC-1510-NPT

Port connections: 1" NPT

Max. working pressure: 150 Bar (2160 PSI)

dc-1510F-75-NPT

Also available with 3/4" NPT ports

   

DC-1510F-H

Port connections: 1" RF

Flanged both sides

150, 300, 600, 900 or 1500#ANSI

DC-1510F-H

Also available with 2" RF ports

DC-1510F-2-H

 

 

DC-1510F-1-U

DC-1510F-U
Port connections: 1" RF
Flanged same side
150, 300, 600, 900 or 1500#ANSI

DC-1510F-2-U

Also available with 2" RF ports

 

 

DC-1510F-Z
Port connections: 1" RF
Flanged opposing sides
150, 300, 600, 900 or 1500#ANSI

DC-1510F-1-Z

Also available with 2" RF ports

 DC-1510F-2-Z

 

 

GENERAL

Measurement

Water-in-oil, BS&W, Water cut

Measurement principle

Advanced digital capacitance

Water in oil range

0 to 50 % standard

 

(50 to 80 % optional)

Analogue output

0 to 50 % (0 to 500,000 ppm) configurable

Resolution

0.001 % (10 ppm)

Accuracy

0.01 % (100 ppm)

Repeatability

Up to 0.01 % (100 ppm)

Temp. compensation

0 to 260 °C

Temp. stability

0.0015 % (15 ppm) water/°C

Certification

European

CE marked

ATEX

Ex II 2G, Ex d IIB T4, Zone 1

CSA

Class 1, Div. 1, Gr. C&D

Corrosion Protection

NACE MR-0175/ISO 15156 2009

sour service compliant

Shipping

DC-1510-NPT

19.5 Kg

DC-1510-F-H

29 to 68 Kg

DC-1510F-U

24 to 44 Kg

DC-1510F-Z

24 to 44 Kg

DC-1510 - all versions

26 cm x 28 cm x 86 cm

MECHANICAL

Material (wetted parts)

316 Stainless standard (Monel 400,

Inconel 625 & Duplex 2205 optional)

O-ring material

Viton A standard (Nitrile & PTFE optional)

Ingress protection

IP66 compliant

Maximum Operating Pressures

Temperature

-6 to 38 °C

65 °C

93 °C

121 °C

Class 150

18.5 Bar

17 Bar

16 Bar

15 Bar

Class 300

49 Bar

48 Bar

47.5 Bar

47 Bar

Class 600

98 Bar

96.5 Bar

95 Bar

94 Bar

Class 900

147 Bar

145 Bar

143 Bar

140.5 Bar

Max. fluid temperature

135 °C (260 °C optional)

Max. ambient temperature

+85 °C

Electrical operating temp.

-40 °C to +85 °C

Storage temperature

-40 °C to +85 °C

ELECTRICAL

Power

 24 V DC@ 150 mA floating

Conduit size

3/4" NPT, 1" NPT & M20

Analogue output

Current

4 to 20 mA isolated, self-powered

Maximum load

600 Ω

Isolating volts

500 V peak

Alarm Relay Setpoint

Relay contacts

SPST 2 amp@ 24 V non-inductive

Delay adjustable

0 to 43 million seconds

Hysteresis adjustable

0 to 49.9 %

Digital Interface

Output 1

RS-232 full duplex (max. 100 m)

Output 2

RS-485 (max. 1500 m)

Speed

9600 Baud